Here you will find presentations given at COMSOL Conferences around the globe. The presentations explore the innovative research and products designed by your peers using COMSOL Multiphysics. Research topics span a wide array of industries and application areas, including the electrical, mechanical, fluid, and chemical disciplines. Use the Quick Search to find presentations pertaining to your application area.

Reactor Design Improvements for a Propane Autothermal Reformer by Simulation of Momentum Flow

F. Cipitì, L. Pino, A. Vita, M. Laganà, and V. Recupero
CNR-ITAE, Messina

The paper presents a two-dimensional model to describe the gas flow in a propane autothermal reactor, developed at the CNR-ITAE Institute, and aimed to design a Beta 5 kWe hydrogen generator, named HYGen II, to be used with Polymer Electrolyte Fuel Cells (PEFCs) for residential applications. The main aim of the mathematical model was to optimize the reactor geometrical key parameters (diameter ...

A Model for Tubular Solid Oxide Fuel Cells

C. Ciano
Politecnico di Torino

In this paper, a model of a tubular fuel cell is proposed and includes thermo-fluid dynamics, chemical reactions and electrochemistry. The main results presented are the temperature distribution, the concentration of species and the polarization curves.

Simulation of the Inverse Extrusion of Brass Rod by the Coupling of Fluid Mechanical, Thermal and ALE Modes

C. Mapelli, and L. Bergami
Dipartimento di Meccanica, Politecnico di Milano

The complete coupling among the Incompressible Navier-Stokes - General Heat Transfer -ALE modes can be a reliable tool for the simulation of the plastic deformation process. This is shown here.

Thermal Dissipation of DIMM Modules in a Tower-BTX Configuration

G. Sorge, G. Cammarata, and G. Petrone
University of Catania

In this paper we study the natural convection for Dual In-Line Memory Module (DIMM) systems. Numerical models are developed using COMSOL Multiphysics. The results, obtained for imposed ambient temperature and operative conditions (power supplied to the CPUs) were produced and complex fluid motion field could be detected.