Quick Search

3D ICP Reactor, Argon Chemistry

Application ID: 8661


3D plasma modeling is possible to do in COMSOL. A square coil is placed on top of a dielectric window and is electrically excited at 13.56MHz. A plasma is formed in the chamber beneath the dielectric window, which contains Argon gas at low pressure (20 mtorr). The gas flows into the process chamber from two 2 inch ports and the gas is extracted through a single 4 inch port. The plasma is sustained via electromagnetic induction where power is transferred from the electromagnetic fields to the electrons.

This application was built using the following:

Plasma Module

The combination of COMSOL® products required to model your application depends on the physics interfaces that define it. Particular physics interfaces may be common to several products (see the Specification Chart for more details). To determine the right combination of products for your project, you should evaluate all of your needs in light of each product's capabilities, consultation with the COMSOL Sales and Support teams, and the use of an evaluation license.